Gear Flow Transmitter NKGF Series | Positive Displacement Flow Meter
- Brand:NOIKE-AH
- Model:NKGF series
Specification
Product Overview
The NOIKE-AH Gear Flow Transmitter NKGF Series is a positive displacement (PD) flow meter designed for precision measurement of high-viscosity liquids such as lubricating oil, hydraulic oil, resin, glue, and other industrial fluids.
Using a pair of precision-machined gears, the transmitter divides the flowing liquid into fixed-volume chambers and accurately measures the flow volume. It provides excellent accuracy, repeatability, and long-term stability, making it suitable for industrial process control, dosing systems, and precision flow monitoring.
Why Choose the NOIKE-AH Gear Flow Transmitter NKGF?
Choosing a Gear Flow Transmitter NKGF is especially beneficial for applications requiring stable measurement of viscous liquids.
The NOIKE-AH Gear Flow Transmitter NKGF offers the following advantages:
- Positive displacement measuring principle for high-accuracy volumetric measurement
- Excellent performance with high-viscosity media
- High repeatability for consistent process control
- Flow measurement independent of turbulence or flow profile
- No straight pipe sections required for installation
- Multiple output options for easy PLC and automation integration
- Available in aluminum, 304, 316, and 316L stainless steel
- Suitable for demanding industrial environments
Working Principle
Positive Displacement Measurement
The Gear Flow Transmitter NKGF operates using the positive displacement principle.
Precision Gear Rotation
Two precision-machined cylindrical gears are installed inside the measuring chamber. As liquid flows through the meter, hydraulic pressure causes the gears to rotate.
Fixed-Volume Chamber Measurement
Each gear rotation divides the liquid into fixed-volume chambers, allowing the meter to measure the actual displaced liquid volume.
Non-Contact Signal Detection
A non-contact sensor detects each passing gear tooth without mechanical contact, ensuring stable signal generation.
Pulse Signal Output
The rotational movement is converted into electrical pulse signals proportional to the instantaneous flow rate. Depending on the selected configuration, these signals can also be converted into analog or digital outputs.
Key Advantages
High Measurement Accuracy
- Standard accuracy: ±0.5%
- High-precision version: ±0.2%
- Repeatability: 0.1%
Suitable for precision flow monitoring and dosing applications.
Excellent Performance with High-Viscosity Liquids
Unlike many other flow measurement technologies, higher liquid viscosity helps reduce internal slippage, contributing to stable measurement accuracy.
Independent of Flow Profile
Measurement accuracy is not affected by:
- Flow velocity distribution
- Turbulence
- Pipeline vibration
No straight pipe sections are required.
Wide Measuring Range
The transmitter provides reliable measurement across a wide operating flow range.
Flexible Signal Integration
Supports multiple industrial output signals, including:
- Pulse Output
- 4–20 mA Analog Output
- RS485 (Modbus)
Suitable for integration with PLCs, SCADA systems, industrial controllers, and process automation equipment.
Technical Specifications
| Parameter | Specification |
|---|---|
| Measurement Principle | Positive Displacement (Gear Type) |
| Accuracy | ±0.5% (Standard), ±0.2% (High Precision) |
| Repeatability | 0.1% |
| Working Pressure | Up to 400 bar (depending on model) |
| Medium Temperature | -40°C to +270°C |
| Output Signals | Pulse, 4–20mA, RS485 (Modbus) |
| Housing Material | Aluminum (AL), 304 SS, 316 SS, 316L SS |
| Protection Rating | IP65 / IP67 |
Performance Parameters:


The sizes are above are for the standard products. We also accept customization based on the customers’site demand.
Industrial Applications
The Gear Flow Transmitter is suitable for precise liquid flow measurement in various industrial applications.
Hydraulic Systems
Real-time monitoring of hydraulic oil flow in hydraulic power units and industrial machinery.
Coating and Adhesive Industry
Accurate dosing and monitoring of resins, glues, and two-component coating materials.
Engine Testing
Precision measurement of fuel consumption and lubrication oil flow during engine testing.
Chemical Dosing Systems
Accurate quantitative measurement of high-value chemical additives and process fluids.
Frequently Asked Questions (FAQ)
What types of liquids can this Gear Flow Transmitter NKGF measure?
It is suitable for lubricating oil, hydraulic oil, resin, glue, chemical liquids, and other high-viscosity industrial fluids.
Does viscosity affect measurement accuracy?
Higher-viscosity liquids generally reduce internal slippage, helping maintain stable measurement accuracy.
Is a straight pipe section required?
No. Measurement accuracy is independent of flow profile, so straight pipe sections are generally not required.
What output signals are available?
Available outputs include Pulse, 4–20mA analog output, and RS485 (Modbus), depending on the selected model.
Do I need straight pipe runs for installation?
No. Due to the PD principle, the gear meter is insensitive to flow profiles and can be installed directly after bends or valves.
Can it measure fluids with particles?
We highly recommend installing a filter at the inlet. The tight tolerances between the gears can be damaged by hard particles.
Table of Contents
Talk With Us
- [email protected]
- +86 180 5512 0225
- +86(0551)-65501008
- Address: 206, Block B, No. 2 Tianda Road, High-tech Zone, Hefei City, Anhui Province, China
- We will respond to you within five minutes.