Specification

Product Features

The thermal level switch NKC-H1304 is designed for reliable point level detection in various industrial applications. Its heat-resistant structure and optimized probe design enable stable operation under different media conditions.

Key Features

  • Equipped with a heat dissipation fin for medium temperatures up to 120°C
  • Cone-shaped probe design helps reduce material adhesion during operation
  • Suitable for detecting:
    • Water-based media
    • High-viscosity media
    • Low-static media
    • Conventional liquid media
    • Powder materials
  • Supports PNP and NPN output configurations
  • Designed for reliable point level detection in industrial processes

Dimensions (unit: mm)

Thermal Level Switch NKC-H1304 series
Thermal Level Switch NKC-H1304 series

Wiring Diagram


Why Choose This Product?

This thermal level switch NKC-H1304 is suitable for applications requiring reliable level detection under varying media conditions. The heat dissipation fin improves performance in elevated-temperature environments, while the cone-shaped probe design helps minimize material buildup. It supports multiple media types and provides flexible PNP/NPN output options for industrial automation systems.


Output Status

For level switches with PNP or NPN output configured as Normally Closed (NC):

  • Green LED ON: No liquid is detected.
  • Red LED ON: The probe is in contact with the liquid.

The LED indication provides a simple visual reference for monitoring the current switching status during operation.


Adjustment Method

Level Switch Calibration Procedure

  1. Suspend the level switch so that the probe is not in contact with the medium.
  2. Rotate the potentiometer clockwise until the red LED turns on.
  3. Keep the probe suspended in air (without liquid contact).
  4. Rotate the potentiometer counterclockwise until the green LED turns on.
  5. Continue rotating one additional full turn counterclockwise to complete the adjustment.

Applications

Suitable for point level detection in industrial systems handling:

  • Conventional liquid media
  • High-viscosity liquids
  • Low-static media
  • Powder materials
  • Medium temperatures up to 120°C

Frequently Asked Questions

What media can this level switch detect?

It is suitable for water-based media, high-viscosity media, low-static media, conventional liquids, and powders.

What is the maximum medium temperature?

The heat dissipation fin design allows operation with medium temperatures up to 120°C.

What output types are available?

The level switch supports PNP and NPN outputs, including Normally Closed (NC) configurations.

How can I verify the switching status?

The LED indicator provides visual feedback:

  • Green LED: No liquid detected
  • Red LED: Liquid detected