Intelligent Thermal Flow Switch with Temperature Monitoring | Color Display Flow Sensor
- Brand: NOIKE-AH
- Range: NK220
Specification
Product Overview
The NOIKE-AH Intelligent Thermal Flow Switch is a compact, maintenance-free flow monitoring solution that combines flow detection and temperature measurement in one device. Based on advanced thermal dispersion technology, it accurately measures the flow of liquids and gases while providing real-time temperature monitoring, programmable switching outputs, and remote signal transmission.
Designed with no moving parts, a 0.96-inch color LCD display, and multiple output options including PNP, NPN, IO-Link, 4–20 mA, and 1–5 V, it is an ideal solution for industrial automation, pump protection, hydraulic systems, and cooling circuits.
Key Features
- Thermal dispersion flow measurement technology
- Integrated flow and temperature monitoring
- Suitable for liquids, gases, and gas-liquid applications
- No moving parts for maintenance-free operation
- Compatible with multiple pipe diameters using a single model
- Extremely low pressure loss
- 0.96-inch color LCD for flow trend and switching status
- Built-in temperature measurement with alarm function
- Remote monitoring capability
- User-friendly button configuration
- IP67 protection for harsh industrial environments
Working Principle
The flow switch operates using the thermal dispersion principle.
Inside the sealed sensing probe are two precision resistors:
- Heated resistor, which functions as the sensing element
- Reference resistor, which remains at the medium temperature
As fluid flows past the probe, heat is carried away from the heated resistor, causing its resistance to change. The electronics continuously compare the resistance difference between the heated and reference resistors to calculate the flow velocity and determine the switching status.
This non-mechanical measuring principle provides stable performance, fast response, and long service life without mechanical wear.
Technical Specifications
| Parameter | Specification |
|---|---|
| Measuring Principle | Thermal Dispersion |
| Suitable Media | Water, Oil, Gas, Gas-Liquid Applications |
| Flow Range | 0.01–2.0 m/s (Water) |
| Medium Temperature | 0–100°C |
| Ambient Temperature | -20 to +80°C |
| Storage Temperature | -20 to +80°C |
| Temperature Accuracy | ±1.5°C (Probe immersed in medium) |
| Power Supply | 24 VDC ±20% |
| Maximum Switching Current | 200 mA (PNP/NPN) |
| Current Consumption | <100 mA |
| Display | 0.96-inch Color LCD |
| Configuration | Button Setting |
| Pressure Rating | 100 bar |
| Response Time | 1–13 s (Typical 2 s) |
| Electrical Protection | Reverse polarity, short circuit, overload protection |
| Protection Rating | IP67 |
| Connection | M12 Connector |
Output Signals
Flow Output
- PNP
- NPN
- IO-Link
- 4–20 mA
- 1–5 V
Temperature Output
- PNP
- NPN
- IO-Link
- 4–20 mA
- 1–5 V
Materials
| Component | Material |
|---|---|
| Housing | Stainless Steel / Engineering Plastic |
| Wetted Parts | 316L Stainless Steel / EPDM |
Typical Applications
The intelligent thermal flow switch is suitable for:
- Low-flow alarm systems
- Pump dry-run protection
- Hydraulic systems
- Pneumatic systems
- Cooling water systems
- Lubrication systems
- Cutting fluid monitoring
- Industrial process automation
- General liquid and gas flow monitoring
Product Advantages
- Simultaneous flow and temperature monitoring
- Maintenance-free operation with no moving parts
- One model fits multiple pipe sizes
- Compact design saves installation space
- Color LCD provides intuitive operating status
- Multiple industrial output options
- Supports remote monitoring and temperature alarms
- Fast response with high reliability
- Easy installation and configuration
- Suitable for demanding industrial environments
Installation Recommendations
For optimal performance:
- Install according to the indicated flow direction.
- Ensure the sensing probe is fully immersed in the process medium.
- Connect the device using the M12 connector.
- Supply power within the specified 24 VDC ±20% range.
- Configure flow and temperature parameters before commissioning.
- Clean the sensing probe periodically when used with contaminated media.
Industries Served
- Industrial Automation
- Machinery Manufacturing
- Hydraulic Equipment
- Pneumatic Systems
- HVAC
- Chemical Processing
- Water Treatment
- Food & Beverage
- Pharmaceutical Manufacturing
- Energy & Utilities
- Process Control
Frequently Asked Questions (FAQ)
What measuring principle does this flow switch use?
It uses the thermal dispersion principle, comparing the temperature difference between a heated resistor and a reference resistor to determine flow velocity.
Can it measure both flow and temperature?
Yes. The device integrates flow monitoring and temperature measurement, with support for temperature alarms and remote monitoring.
What types of media are supported?
It is compatible with water, oil, gases, and other compatible liquid or gas applications.
What output options are available?
The flow and temperature outputs support PNP, NPN, IO-Link, 4–20 mA, and 1–5 V.
Does the device require regular maintenance?
No. Since it has no moving parts, routine mechanical maintenance is unnecessary. For contaminated media, periodic cleaning of the probe is recommended.
Is it suitable for pump protection?
Yes. It is widely used for low-flow detection, flow interruption monitoring, and pump dry-run protection.
What is the protection rating?
The device has an IP67 protection rating for reliable operation in demanding industrial environments.
Can the specifications be customized?
Yes. Certain specifications and configurations can be customized to meet specific application requirements.
Why Choose the NOIKE-AH Intelligent Thermal Flow Switch?
The NOIKE-AH Intelligent Thermal Flow Switch combines thermal dispersion flow measurement, integrated temperature monitoring, a color LCD display, and flexible industrial outputs into one compact, maintenance-free device. Its high reliability, low pressure loss, and support for IO-Link, analog outputs, and programmable switching signals make it an ideal choice for industrial automation, equipment protection, and modern process control systems.