Flow Temperature Pressure Integrated Sensor NKT500 | Industrial Multi-Parameter Flow Meter

  • Brand:NOIKE-AH
  • Model:NKT500

Specification

Product Overview

The NOIKE-AH Flow Temperature Pressure Integrated Sensor NKT500 is an intelligent flow monitoring solution that simultaneously measures flow rate, temperature, and pressure in a single device. Designed for industrial automation and process control, it provides real-time flow, totalized flow, temperature, and pressure display, while supporting multiple analog, digital, and alarm outputs for seamless integration into PLC, DCS, and SCADA systems.

With no moving parts, the meter offers excellent long-term stability, minimal maintenance, and reliable performance for both liquid and gas applications.


Key Features

  • Simultaneous measurement of flow, temperature, and pressure
  • OLED LCD display for:
    • Instantaneous flow
    • Totalized flow
    • Temperature
    • Pressure
  • Supports both liquid and gas measurement
  • Three independent 4–20 mA analog outputs
  • Three programmable alarm outputs for flow, pressure, and temperature
  • RS485 digital communication
  • User-configurable pulse output (up to 1 kHz)
  • Five-point flow linearization for improved accuracy
  • No moving parts for maintenance-free operation
  • Not affected by pipeline static pressure
  • Simple installation without on-site calibration

Working Principle

The multi-parameter flow meter continuously measures the flow characteristics of the process medium while simultaneously monitoring temperature and pressure. Internal compensation algorithms process these parameters to provide accurate real-time flow measurement and stable output signals.

Integrated electronics calculate:

  • Instantaneous flow rate
  • Total accumulated flow
  • Process temperature
  • Pipeline pressure

The measured values are displayed locally and transmitted through analog and digital communication interfaces for industrial control systems.


Technical Specifications

Parameter Specification
Measured Media Liquids & Gases
Liquid Flow Range 0.4–25,000 L/min (depends on pipe size)
Gas Flow Range Calculated according to application
Pressure Range 0–1.0 MPa
Standard Pressure Rating 1.0 MPa
Optional Pressure Rating 1.6 MPa / 2.5 MPa
Medium Temperature -20°C to +80°C
Optional Medium Temperature -40°C to +350°C
Ambient Temperature -10°C to +65°C
Flow Accuracy < ±2% F.S.
Pressure Accuracy < ±0.5% F.S.
Temperature Accuracy < ±1°C
Repeatability <2% of actual flow
Power Supply 18–30 VDC
Display OLED LCD (1.5″)
Linearization Five-point flow linearization
Wetted Materials Alumina / SUS304 Stainless Steel

Output Signals

Analog Output

  • Three independent 4–20 mA outputs
  • Linear relationship with:
    • Flow
    • Temperature
    • Pressure
  • User configurable measurement ranges
  • Maximum load: 500 Ω

Digital Output

  • RS485 communication
  • User-configurable pulse output
  • Maximum pulse frequency: 1 kHz
  • Pulse scaling customizable (e.g., 1 pulse/L or 1 L/pulse)

Alarm Outputs

  • Three independent programmable alarm switches
  • Full-range configurable setpoints
  • Switching capacity:
    • 24 VDC / 400 mA

Process Connections

Thread Connections

  • G1/2
  • G3/4
  • G1
  • G1-1/2
  • G2

Flange Connections

  • DN15–DN250
  • GB9119-2000 Standard

Typical Applications

The multi-parameter flow meter is suitable for numerous industrial applications, including:

  • Cooling water systems
  • Circulating water monitoring
  • Lubrication systems
  • Hydraulic oil circuits
  • Steam flow measurement
  • Organic and inorganic chemical solutions
  • Oxygen flow monitoring
  • Nitrogen flow monitoring
  • Ammonia systems
  • Natural gas monitoring
  • Sprinkler systems
  • Sewage protection
  • Freeze protection systems
  • Fuel consumption monitoring
  • Industrial process automation

Product Advantages

  • Simultaneous monitoring of flow, pressure, and temperature
  • One instrument replaces multiple field devices
  • Supports both gas and liquid applications
  • Maintenance-free design with no moving mechanical parts
  • High reliability in continuous industrial operation
  • OLED display for clear local visualization
  • Multiple analog and digital communication options
  • User-programmable alarms and pulse outputs
  • Easy installation without field calibration
  • Stable measurement unaffected by static pipeline pressure

Installation Recommendations

For optimal performance:

  • Select the appropriate process connection based on pipeline size.
  • Install according to the indicated flow direction.
  • Ensure the pipeline remains completely filled during liquid measurement.
  • Avoid installing near severe vibration or strong electromagnetic interference.
  • Connect the power supply within the specified 18–30 VDC range.
  • Configure alarm outputs and communication parameters before system commissioning.

Industries Served

  • Water Treatment
  • Chemical Processing
  • Oil & Gas
  • Power Generation
  • HVAC
  • Food & Beverage
  • Pharmaceutical Manufacturing
  • Metallurgy
  • Machinery Manufacturing
  • Environmental Protection
  • Industrial Automation
  • Process Control

Frequently Asked Questions (FAQ)

What parameters can this flow meter measure?

It simultaneously measures flow rate, total flow, temperature, and pressure.

Can it measure both liquids and gases?

Yes. The instrument is designed for both liquid and gas applications.

Does it support industrial communication?

Yes. It supports RS485 communication, three 4–20 mA analog outputs, programmable pulse output, and three independent alarm outputs.

Is field calibration required?

No. The meter is designed for easy installation without on-site calibration or debugging.

Does the meter have moving parts?

No. Its no-moving-parts design minimizes wear and provides maintenance-free operation.

Can alarm values be configured?

Yes. Users can independently configure three alarm points for flow, pressure, and temperature across the full measuring range.

What process connections are available?

The meter supports threaded connections (G1/2–G2) and flange connections (DN15–DN250).

Is high-temperature customization available?

Yes. The standard medium temperature range is -20°C to +80°C, with optional customization up to -40°C to +350°C.


Why Choose the NOIKE-AH Flow Temperature Pressure Integrated Sensor NKT500?

The NOIKE-AH Flow Temperature Pressure Integrated Sensor NK500 combines flow measurement, pressure monitoring, temperature sensing, local display, analog outputs, digital communication, and programmable alarms into a single intelligent instrument. Its maintenance-free design, flexible output options, and compatibility with liquid and gas applications make it an ideal solution for modern industrial automation and process monitoring.

Table of Contents

Talk With Us

Get An Instant Quotation Now